Manufacturer: Axel Semrau
Odor On-line Chromatograph
Continuous, automatic odorant measurement in gas networks.
- Method
- Gas chromatography
- Odorants
- THT, TBM, MES, Spotleak 1005, …
- Gas types
- Natural gas, LPG, biogas, town gas, gas-air mixtures
- Standards
- ISO 6326, ISO 19739, DIN 51855-7, DVGW G 280
About the product
It measures odorant concentration in the gas network continuously and automatically by gas chromatography. Remote monitoring and alarms deliver the most complete safety while keeping operating and maintenance costs as low as possible. Its records are stored in a form that can serve as legal evidence.
Key features
- 01 Continuous, automatic measurement of odorant intensity in gas networks
- 02 Comprehensive safety with remote control and alarms
- 03 Keeps operating and maintenance costs to a minimum
- 04 Quality control of alkali sulphides, mercaptans, H₂S and COS
- 05 Works with all odorants (THT, TBM, MES, Spotleak 1005, blends and others)
- 06 Works with all gas types (natural gas, LPG, biogas, town gas, gas-air mixtures)
- 07 User-friendly Windows software with status screen
- 08 Database records suitable as legal evidence; flexible export, analogue and relay outputs, digital inputs, remote data transfer
- 09 Complies with ISO 6326, ISO 19739, DIN 51855-7 and DVGW G 280 reference methods
Data sheet
Technical data
| Component | Measuring range | Accuracy |
|---|---|---|
| THT | 0,1–100 mg/m³ | ±%0,1 |
| TBM | 0,01–100 mg/m³ | ±%0,01 |
| EM | 0,01–100 mg/m³ | ±%0,01 |
| H₂S | 0,1–100 mg/m³ | ±%0,1 |
| MES | 0,1–100 mg/m³ | ±%0,1 |